Skip to end of banner
Go to start of banner

2022-03-30 Data Import Subgroup meeting

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

Recordings are posted Here (2022+) and Here (pre-2022)                   Slack channel for Q&A, discussion between meetings

Requirements details Here                                                                    Additional discussion topics in Subgroup parking lot


Attendees: Ann-Marie Breaux (Deactivated) 

Lotus

Morning Glory

  • Morning Glory Folijet and Spitfire planning: dashboard where you can see the current scope and status of Data Import work for Morning Glory
  • Current work:
    • Adding Admin notes to the 3 Inventory field mapping screens
    • Field protections: fixed 1 bug for Lotus, rest of the fixes will be in Morning Glory
    • Will soon be starting log refinements (deleting logs)

Agenda topics:

Lotus Bugs

  • Deleting job logs
    • Will be possible from the UI on the Data Import landing page and the View all page, plus by directly hitting an endpoint in the backend
    • OK that the logs are delete and cannot be restored?
    • OK that (for now) deleting logs will be part of the Data Import: All permissions?



  • MARC-MARC matching
    • Lotus: Allows for any field in a MARC record except
    • Are these needed in Morning Glory?
      • Matching for 100-899 fields? (I think they work, but not heavily tested yet)
      • Repeatable fields (e.g. 024, 035)
        • Incoming record: Only first version of the field is considered (doublechecking with the dev on whether it's the first field that has the requested indicator(s) and/or subfield, or just the first field, regardless of indicators/subfield)
        • If it takes Ind 1, Ind 2, Subfield into account (in addition to the data)
        • Does FOLIO need to check all incoming 024s against all 024s in the existing SRS records? Or just the first?
        • Wildcards for Ind 1, Ind 2, Subfield (repeatable or non-repeatable fields)
          • Needed?
    • Additional info from A-M/Igor:
      • Let's pretend that these fields are in an incoming record: (Field Ind1 Ind2 Subfield)

        • 024 _ _ $a 12345
          024 1 1 $a 45678
          024 1 _ $x 67890
          024 2 2 $x 67890
      • And the fields in the existing SRS record are

        • 024 2 2 $x 67890
          024 _ _ $a 12345
          024 1 _ $x 13579
          024 1 1 $a 45678
          024 1 _ $x 67890

      • I understand that for repeatable fields, FOLIO Lotus only pays attention to the first incoming field, not the rest, but compares to any matching fields in the existing record.

      • Now - setting up different match profiles, I want to be sure I understand the logic that is in place now:

      • If the match profile is 024 _ _ $a: 

        • Matches, because the incoming first 024 looks for an existing 024 with blank indicators and $a and the same value (even though that is the second 024 in the existing record)


        If the match profile is 024 1 1 $a:

        • Matches, because the first incoming 024 with indicators 11 and $a (which is the second 024 in the incoming file) looks for an existing 024 with indicators 11 and $a and the same value (which is the fourth 024 in the existing record)


        If the match profile is 024 1 _ $x:

        • Matches, because the first incoming 024 with indicators 1_ and $x (which is the third 024 in the incoming file) looks for an existing 024 with indicators 1_ and $x and the same value (which is the fifth 024 in the existing record)


        If the match profile is 024 2 2  $x:

        • Matches, because the first incoming 024 with indicators 22 and $x (which is the fourth 024 in the incoming file) looks for an existing 024 with indicators 22 and $x and the same value (which is the first 024 in the existing record)
      • However!
        Let’s pretend the incoming record looks like this:
        • 024 1 1 $a 12345
          024 1 1 $a 45678
      • And the existing SRS record is
        • 024 1 1 $a 45678
      • If the match profile is 024 1 1 $a, SRS does not match, even though “024 1 1 $a 45678” is present in both incoming and existing records.
        SRS starts searching a field, that is specified in match profile, scrolling the incoming record from the very beginning, as usual, and takes the first occurrence of <024 1 1 $a>. The first occurrence is “024 1 1 $a 12345". So, SRS takes “024 1 1 $a 12345” and can’t find it in the existing record 


    • Future topics:
      • Results of Feb 2022 survey 
      • See if we can make the 005 modifiable, so that the existing one can be copied into a 9xx field via a MARC modification rule so that we can keep the date of last OCLC edit to a record (Lloyd)


  • No labels